Abstract
The present work aims at accessing the stability of intern quality control samples (IQC), produced with low reactivity limit (weakly reactive), for persistency of anti-HIV antibodies reactivity after long-term storage at -20° C. The analyzed sera – two HIV strongly positive lots (numbers 067 and 075) and two HIV weakly positive lots (IQC061 and IQC067) with standardized dilutions for enzyme-linked immunosorbent assay - ELISA (third generation) and Western blot – were derived from a stability study carried out by Castejon et al (2014). In this re-evaluation, after 13 years of storage, different serological assays available in the laboratory were used. The results revealed the anti-HIV antibodies stability maintenance; however the serum lots – IQC061 and IQC067 – were HIV strongly positive in the fourth generation assays and also, there was reactivity variation of some bands in the Western blot. Due to the inclusion of new methodologies on the market, IQC (weakly reactive) that was standardized for a specific test and storage for long-term may not perform its intended purpose.
References
Gray JJ, Wreghitt TG, McKee TA, McIntyre P, Roth CE, Smith DJ, et al. Internal quality assurance in a clinical virology laboratory. I. Internal quality assessment. J Pathol. 1995;48(2):168-1. https://doi.org/10.1136/jcp.48.2.168.
Castejon MJ, Yamashiro R, Oliveira CAF, Ueda M. Implementation of a strategy for improving the serological diagnosis of HIV/AIDS by introducing the internal quality control. Rev Inst Adolfo Lutz. 2010;69(2):157-64. https://doi.org/10.53393/rial.2010.v69.32650.
Mendes ME. Estudo de estabilidade de amostras no laboratório clínico: garantia de qualidade dos resultados e da segurança para o paciente. J. Bras. Patol. Med. Lab.2019; 55(3):244-5. https://doi.org/10.5935/1676-2444.20190030.
Jamtsho R. Stability of lyophilized human serum for use as quality control material in Bhutan. Ind J Clin Biochem. 2013; 28(4):418–21. https://doi.org/10.1007/s12291-013-0328-x.
Kulkarni S, Pierre SA, Kaliaperumal R. Efficacy of pooled serum internal quality control in comparison with commercial internal quality control in clinical biochemistry laboratory. J Lab Physicians. 2020; 12(3):191–5. https://doi.org/ 10.1055/s-0040-1721151.
Dhoot A, Mammen JJ, Mathews NS, Rajesh Kannangai R, Daniel D, Prasannakumar S. Internal quality control for HIV testing of blood donors - dried tube specimen as a cost-effective alternative. Asian J Transfus Sci 2022;16:231-7. https://doi.org/10.4103/ajts.ajts_75_21.
International Standards Organization. ISO Guide 34: General requirements for the competence of reference material producers. Geneva, Switzerland, 2009.
Associação Brasileira de Normas Técnicas. ISO Guia 35: Materiais de referência – Princípios gerais e estatísticos para certificação. Brasil, 2012.
Castejon MJ, Yamashiro R, Oliveira CC, Olivieri JC, Oliveira CAF, Ueda M. Homogeneity study of the internal quality control sera for immunodiagnosis of HIV/AIDS. J Bras Patol Med Lab. 2014; 50(1):46-52. https://doi.org/10.1590/S1676-24442014000100006.
Castejon MJ, Yamashiro R, Oliveira CC, Granato D, Oliveira CAF, Ueda M. Study on the stability of internal quality control sera for HIV/AIDS immunodiagnostic tests. J Bras Patol Med Lab. 2014; 50(1):36-45. https://doi.org/10.1590/S1676-24442014000100005.
World Health Organization. WHO manual for the preparation of reference materials for use as secondary standards in antibody testing. Geneva, 2022. [Acesso em 20 mai. 2024]. Disponível em: https://www.who.int/publications/m/item/who-manual-for-reference-material-for-antibody-testing.
Gislefoss RE. Quality aspects of long-term stored samples. Studies in the Janus Serum Bank of Norway [Doctoral dissertation]. Oslo: University of Oslo; 2010. [Acesso em 20 mai. 2024]. Disponível em: https://www.duo.uio.no/handle/10852/27900?show=full.
Ellervik C, Vaught J. Preanalytical variables affecting the integrity of human biospecimens in biobanking. Clin Chem. 2015;61(7):914-34. https://doi.org/10.1373/clinchem.2014.228783.
Pawlik-Sobecka L, Sołkiewicz K, Kokot I, Kiraga A, Płaczkowska S, Schlichtinger AM, et al. The influence of serum sample storage conditions on selected laboratory parameters related to oxidative stress: A preliminary study. Diagnostics. 2020;10(1):51. https://doi.org/10.3390/diagnostics10010051.
Jensen CZ, Nygaard B, Faber J, Pedersen PL, Larsen MK, Kanters JK, et al. Long-term stability of thyroid peroxidase antibody (anti-TPO) in serum in the Danish general suburban population study. Clin Chem Lab Med. 2023; 61(9):1590–6. https://doi.org/10.1515/cclm-2022-0845.
Venelinov T, Sahuquillo A. Optimizing the uses and the costs of reference materials in analytical laboratories. Trends Anal Chem. 2006;25(5):528-33. https://doi.org/10.1016/j.trac.2006.02.006.
Dard C, Bailly S, Drouet T, Fricker-Hidalgo H, Brenier-Pinchart MP, Pelloux H. Long-term sera storage does not significantly modify the interpretation of toxoplasmosis serologies. J Microbiol Methods. 2017;134(1):38-45. http://dx.doi.org/10.1016/j.mimet.2017.01.003.
Plebani M, Laposata M, Lippi G. A manifesto for the future of laboratory medicine professionals. Clin Chim Acta. 2019;489(1):49-52. http://dx.doi.org/10.1016/j.cca.2018.11.021.
Plebani M, Aita A, Sciacovelli L. Patient safety in laboratory medicine. In: Donaldson L, Ricciardi W, Sheridan S, Tartaglia R. Textbook of patient safety and clinical risk management [Internet]. Cham: Springer; 2021. v. 24. https://doi.org/10.1007/978-3-030-59403-9_24.
Plebani M. Value-based laboratory medicine: the time is now. Clin Chem Lab Med 2024; 62(4):579-80. https://doi.org/10.1515/cclm-2023-1095.
São Paulo. Secretaria de Estado da Saúde. Coordenadoria de Controle de Doenças. Manual técnico para implementação do controle de qualidade interno nos procedimentos laboratoriais para diagnóstico sorológico da infecção pelo HIV no estado de São Paulo. São Paulo: IAL; 2007. [Acesso em 20 mai. 2024]. Disponível em: https://pesquisa.bvsalud.org/brasil/resource/pt/biblio-933229.
Ministério da Saúde (BR). Portaria SVS/MS nº 29, de 17 de dezembro de 2013. Aprova o manual técnico para o diagnóstico da infecção pelo HIV em adultos e crianças e dá outras providências. Brasília; Diário Oficial da União. Dec. 18, 2013. Seção 1; 245.
World Health Organization. Consolidated guidelines on HIV testing services. 5Cs: consent, confidentiality, counselling, correct results and connection. Geneva, 2015. [Acesso em 21 mai. 2024]. Disponível em: https://iris.who.int/handle/10665/179870.
Alexander TS. Human immunodeficiency virus diagnostic testing: 30 years of evolution. Clin Vaccine Immunol. 2016;23(4):249-53. https://doi.org//10.1128/CVI.00053-16.
Williams E, Moso M, Lim C, Chibo D, Nicholson S, Jackson K, et al. Laboratory diagnosis of HIV: a contemporary overview in the Australian context. Pathology. 2023;55(5):610-20. https://doi.org//10.1016/j.pathol.2023.04.001.
Tworoger SS, Hankinson S E. Collection, processing, and storage of biological samples in epidemiologic studies: sex hormones, carotenoids, inflammatory markers, and proteomics as examples. Cancer Epidemiol Biomarkers Prev. 2006; 15(9):1578-81. https://doi.org//10.1158/1055-9965.EPI-06-0629.
Castejon MJ, Yamashiro R, Oliveira CC, Oliveira CAF, Ueda M. Stability of anti-HIV antibodies in serum samples stored for two to eighteen years periods. J Bras Patol Med Lab. 2014;50(4):272-77. https://doi.org//10.5935/1676-2444.20140026.
Castejon MJ, Yamashiro R, Oliveira CAF. Manual técnico - Programa de controle de qualidade interno em ensaios sorológicos para HIV/aids. 2016; p.24. [Acesso em 21 mai. 2024]. Disponível em: https://saude.sp.gov.br/resources/editorinplace/ial/2016_7_15/manualtecnico_cqi_hiv_bvs_maio_2016.pdf.
Laperche S, Eughouzzi MH, Rannou C, Faucher V. Western-blot ou immunoblot VIH? Immunoanal Biol Spéc. 1997;12(4):173-80. https://doi.org/10.1016/S0923-2532(97)89653-6.
Simundic A-M, Lippi G. Preanalytical phase – a continuous challenge for laboratory professionals. Biochem Med. 2012;22(2):145–9. https://doi.org/10.11613/bm.2012.017.
Cuhadar S, Koseoglu M, Atay A, Dirican A. The effect of storage time and freeze-thaw cycles on the stability of serum samples. Biochem Med. 2013;23(1):70-7. https://doi.org/10.11613/bm.2013.009.
Englezopoulou A, Kechagia M, Chatzikiriakou R, Kanellopoulou M, Valenti M, Masedu F. Pre analytical errors as quality indicators in clinical laboratory. Austin J Public Health Epidemiol. 2016;3(5):1048. [Acesso em 21 mai. 2024]. Disponível em: https://austinpublishinggroup.com/public-health-epidemiology/fulltext/ajphe-v3-id1048.php.
This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright (c) 2024 Márcia Jorge Castejon, Karen Cristina Rolim Madureira, Meire Bocoli Rossi, Elaine Lopes de Oliveira, Juliana Failde Gallo, Rosemeire Yamashiro, Francisco Erisnaldo Nunes