Abstract
Training programs designed for food handlers are an effective way to spread the knowledge and to promote improvements on the hygienic conditions of food establishments. This study aimed at evaluating the effect of a training course on good handling practices for food handlers of selected restaurants in the region of Ouro Preto, MG, Brazil, by using ATP-bioluminescence assay. This test was used to quantify the organic load, measured by “Relative Light Units – RLU”, in samples collected from workers hands, surfaces of work benches and utensils, which were randomly selected in each restaurant. After training, a significant improvement in the hygienic conditions was observed, as evidenced by the decrease in the RLU values in samples from all restaurants. Despite the decreased RLU values, some surfaces did not reach the recommended value for surfaces samples in the satisfactory hygienic conditions. The ATP-bioluminescence test showed to be effective for evaluating the training success, and could be a powerful tool when applied in training programs at food services, and in association with the conventional microbiological methodologies. In spite of the reduction in RLU values, indicating improvements in hygienic conditions, the training and monitoring programs should be continued.References
1. Akutsu RC, Botelho RA, Camargo EB, Sávio KEO, Araujo WC. Adequação das boas práticas de fabricação em serviços de alimentação. Rev Nutr. 2005;18(3):419-27.
2. Andrade NJ. Higiene na indústria de alimentos: avaliação e controle da adesão e formação de biofilmes bacterianos. São Paulo: Varela; 2008.
3. Garcia LP, Sant’Anna AC, Magalhães LCGd, Aurea AP. Gastos com saúde das famílias brasileiras residentes em regiões metropolitanas: composição e evolução no período 1995-2009. Ciênc Saúde Coletiva. 2013;18:115-28.
4. Instituto Brasileiro de Geografia e Estatística -IBGE. Pesquisa de orçamentos familiares 2008-2009: despesas, rendimento e condições de vida. Rio de Janeiro: IBGE; 2010. [acesso 2013 Jan 31]. Disponível em: [http://www.ibge.gov.br/home/estatistica/populacao/condicaodevida/pof/2008_2009/POFpublicacao.pdf].
5. Cavalli SB, Salay E. Gestão de pessoas em unidades produtoras de refeições comerciais e a segurança alimentar. Rev Nutr. 2007; 20(6):657-67.
6. Scallan E, Hoekstra RM, Angulo FJ, Tauxe RV, Widdowson MA, Roy SL, et al. Foodborne illness acquired in the United States-major pathogens. Emerg Infect Dis. 2011;17(1):7-15.
7. Dewall CSHG, Hicks G, Barlow K, Alderton L, Vegosen L. Foods associated with foodborne ilness outbreaks from 1990 through 2003. Food Protection Trends. 2006;26(7):466–73.
8. Brasil. Ministério da Saúde. Resolução RDC 216 de 15 de Setembro de 2004. Dispõe sobre Regulamento Técnico de Boas Práticas para Serviços de Alimentação. Diário Oficial [da] União da República Federativa do Brasil. Brasília, DF, 2004.
9. Shama G, Malik DJ. The uses and abuses of rapid bioluminescence-based ATP assays. Int J Hyg Environ Health. 2013;216(2):115-25.
10. Aycicek H, Oguz U, Karci K. Comparison of results of ATP bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen. Int J Hyg Environ Health. 2006;209(2):203-6.
11. Hawronskyj JM, Holah J. ATP universal hygiene monitor. Trends Food Sci Technol. 1997;8:79-84.
12. Santos NDV, Rotta ET, Silva CF, Deutschendorf C, Santos RP. Avaliação da limpeza terminal em uma unidade para pacientes portadores de microrganismos multirresistentes. Revista HCPA. 2013;33(1):7-14.
13. Cruz AG, Cenci SA, Maia MCA. Quality assurance requirements in produce processing. Trends Food Sci Technol. 2006;17:406-11.
14. Pragle AS, Harding AK, Mack JC. Food workers’ perspectives on handwashing behaviors and barriers in the restaurant environment. J Environ Health. 2007;69(10):27-32.
15. Pinto UM, Cardoso RR, Vanetti MCD. Detecção de Listeria, Salmonella e Klebsiella em serviço de alimentação hospitalar. Rev Nutr. 2004;17(3):319-26.
16. Saúde OMD. Segurança básica dos alimentos para profissionais de saúde. São Paulo: Roca; 2002.
17. Ana BAO, Cunha DT, Stedefeldt E, Capalonga R, Tondo EC, Cardoso MRI. Hygiene and good practices in school meal services: Organic matter on surfaces, microorganisms and health risk. Food Control. 2014;40;120-6.
18. Andrade NJ, Silva RMM, Brabes KCS. Avaliação das condições microbiológicas em Unidades de Alimentação e Nutrição. Ciênc Agrotec. 2003; 27(3):590-6.
19. Costa PD. Avaliação da técnica de ATP bioluminescência no controle dos procedimentos de higienização na indústria de alimentos [dissertação]. Viçosa: Universidade Federal de Viçosa; 2001.
20. Saccol ALF, Rubim BA, Mesquita MO, Welter L. Importância de treinamento de manipuladores em boas práticas. Discip Sci. 2006;7(1):91-9.
21. Oliveira ABA, Cunha DT, Stedefeldt E, Capalonga R, Tondo EC, Cardoso MRI. Hygiene and good practices in school meal services: Organic matter on surfaces, microorganisms and health risks. Food Control. 2014;40:120-126.
22. Colombo SS. Qualidade: sua parceria no sucesso. Nutr Pauta. 1999;7(36):37-8.
23. Panetta JC. O manipulador: fator de segurança e qualidade dos alimentos. Hig Alim. 1998;12(57):8-10.
Neto MS. Diagnóstico situacional da utilização das ferramentas de segurança na produção de alimentos nas cozinhas das unidades de alimentação e nutrição dos hospitais de Brasília/DF [dissertação]. Brasília: Universidade de Brasília; 2006.
25. Costa PD, Andrade NJ, Brandão SCC, Passos FJV, Soares NFF. ATP-bioluminescence assay as an alternative for hygiene-monitoring procedures of stainless steel milk contact surfaces. Braz J Microbiol. 2006;37(3):345-9.
26. Oliveira TD, Canettieri ACV. Eficiência dos métodos microbiológicos e de ATP-bioluminescência na detecção da contaminação de diferentes superfícies. Rev Inst Adolfo Lutz. 2010;6(4):467-74.
27. Griffith C. Improving surface sampling on detection of contamination. Cambridge: Cambridge Woodhead Publishing; 2005.
28. Zottola EA. Microbial attachment and biofilms formation: a new problem for the food industry. Food Technol. 1994;48:107-44.
29. Sherlock O, O’Connell N, Creamer E, Humphreys H. Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanliness. J Hosp Infec. 2009;72:140-6.
30. Keskinen LA, Annous BA. Efficacy of adding detergents to sanitizer solutions for inactivation of Escherichia coli O157:H7 on Romaine lettuce. Int J Food Microbiol. 2011;147(3):157-61.
31. Srey S, Jahid IK, Ha S-D. Biofilm formation in food industries: A food safety concern. Food Control. 2013;31(2):572-85.
This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright (c) 2013 Instituto Adolfo Lutz Journal