Abstract
The authors report a retrospective study realized with hematimetrics values (hemoglobin, hematocrit and erythrocyte), Red blood cell indexes (mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration) and leukocyte, obtained from 3 years (1988-1990), presented by 2 semi-automatic hematology analyzers, priorly calibrated with primary standards and control sample, in order to obtain target values (average on the daily means), that will be used in monitoring the accuracy of these equipments. Firstly the means, the medians, the modes and the frequencies from first 1000 determinations of 1988, were calculated, in order to assess the distributions of the studied population. Secondly, a retrospective statistical study made by a microcomputer, was performed, to analyse 613 routines with 392,000 determinations from 56,000 patients registered at the Health Centers of the ERSA 2, São Paulo Cíty; the arithmetical means, the standard deviations, and the variation coefficients were calculated, and the medians and the maximun and minimun arithmetical means of each year and of the 3 years in question were determined. From the relationship among the hematimetric values, empirical formulas were obtained, to be used in the control of the hematological analyzers. The obtained target values were: Hemoglobin 13.4 g/dL, Hematocrit 40.1%, Erythrocyte 4.63xl06/mm3, mean corpuscular volume 86,7 µ3, mean corpuscular hemglobin 29.1 pg, mean mean corpuscular hemoglobin concentration 33,5% and Leukocyte 7.91 x 10 /mm3. The reference intervals of the target values are presented with 1 and 2 Standard deviations.
References
2. BAVER, J.D. – Clinical laboratory methods. 9th. ed, St. Louis, C.V. Mosby, 1982. p.14.
3. BORGFS, D.R.; FILGUElRAS, T.E.; BERUNGERI, J.C.; BORGFS, D.S.R. - Avaliação, após 5 anos de uso, de programa de controle de qualidade de contadores hematológícos de múltiplos canais. Rev. Bras. Pat. Clin. 17(4):143-46, 1981.
4. BORGES, D.R. - "Valores-alvo"de índices eritrocitários no controle de qualidade em hematimetria. Rev. Bras. Pat. Clin. 23(5):135-37,1987.
5. BULL, B.S.; ELASHOFF, R.M.; HEILBRON, D.C.; COUPERUS, J. - A study of various estimators for the derivation of quality control procedures from patient erythrocyte indices. Am. J. Clin. Pathol. 61:473-481, 1974.
6. BULL, B.S. & HAY, M.S. - Are red blood cell indexes international? Arch: Pathol. Lab. Med. 109:604.{l6, 1985.
7. CEMBROWSKI, G.S.; WFSTGARD, J.O. – Quality control of multichannel hematology analyzers: evaluation of Bull's Algorithm. Am. J. Clin. Pathol. 83(3):337-45, 1985.
8. DORSEY, D.B. - Quality control in hematology. Am. J. Clin. Pathol. 40:457-64, 1963.
9. ENGLAND, J.M.; WALFORD, D.M.; WATERS, D.A.W. - Re-assessment of the reliability of the haematocrit. Brit. J. Haematol. 23:247-56, 1972.
10. GILMER Jr, P.R.; WILLIAMS, L.J.; KOEPKE, IA.; BULL, B.S. - Calibration methods for automated hematology instruments. Am. J. Clin. Pathol. 68:185-190,1977.
11. GILMER Jr. P.R. & WILLIAMS, LJ. - The status of methods of calibration in hematology. Am. J. Clin. Pathol. 74(4):600-05,1980.
12. GULATI, G. & HYUN, B.H. - Quality control in hematology. Clin. Lab. Med. 6(4):675-88.1986.
13. GUSHIKEN, E.Y.; MUNHOZ, M.A.G.; KITAMURA, C.; ZAMFIROV, V.M.C.; NIERO, L.I. - Padronização do preparo de lisados hemoglobínícos estáveis para uso em laboratório de saúde pública. Rev. Inst. Adolfo Lutz. 51(1/2)83-86,1991.
14. KOEPKE, JA & PROTEXTOR, TJ. – Quality assurance for multichannel hematology instruments. Four years experience with patient mean erythrocyte indices Am. J. Clin. Pathol. 75:28-33,1981.
15. LEVY, W.C.; BULL, B.S.; KOEPKE, JA – The incorporation of red blood cell index mean data into quality control programs. Am. J. Clin Pathol. 86:193-99,1986.
16. LOTSPEICH-STEININGER. C.A.; STIENE-MARTIN, E.A.; KOPKE, J.A. - Clinical hematology: principles, procedures, correlations. Philadelphia, J. B. Lippincott, 1992, p. 552-3.
17. MUNHOZ, MAG.; GUSHIKEN, E.Y.; PACHECO, N.R.; CAMPA, S. B.; KITAMURA, C.; AZEVEDO NETO, R.S. - Uso de amostra controle na avaliação da reprodutibilidade de equipamentos semi-automatizados em hematologia laboratorial: uma proposta de controle de qualidade para laboratórios de saúde pública. Rev. Inst. Adolfo Lutz, 51(1/2):41-45, 1991.
18. ROSENFELD, L.G.M.: ANDRADE. M.; BORGFS, D.R. Controle de qualidade em exames hematológicos, An. Paul. Med. Cir. 104:92-6, 1977.
19. SIMMONS, A. - Hematology: a combined theoretical & technical approach. Philadelphia, W.B. Saunders, 1989, p. 190-1.
This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright (c) 1993 Instituto Adolfo Lutz Journal